Cli-Mate Wet Underfloor Heating Standard Output Kit – 30m² to 200m²
The Cli-Mate Wet Underfloor Heating Standard Output systems are the perfect choice for homeowners and tradespeople looking to install a wet underfloor heating pack. The Cli-Mate Wet Underfloor Heating Standard Output Kit is designed for controlling the temperature of a single room on the ground floor of new build or renovation projects with solid floor constructions. The pipes are fitted onto floor insulation using clips and covered with screed before laying the floor covering on top. Each pack is designed to cover a specific area in square meters when the pipe is installed at 200mm spacing and can provide a certain heating output.
Standard Output Pack: Estimated heating output | ||||
Proposed Floor Finish | Thermal Resistance (Estimate) | Pipe Spacing (mm) | Maximum UFH Output W/m² | *Floor Surface Temperature (ºC) |
Tile / Stone | 0.02 W/m²K | 200 | 115 | 30 |
Vinyl | 0.05 W/m²K | 200 | 90 | 28 |
Timber | 0.10 W/m²K | 200 | 75 | 27 |
Carpet | 0.15 W/m²K | 200 | 65 | 26 |
The estimated heating outputs according to BS EN 1264 for a 16mm UFH pipe within a 75mm floor screed are based on achieving a 20ºC internal room temperature with a mean water temperature of 45ºC (50ºC Flow, 40ºC Return). These figures are suitable for systems fed from conventional heat sources such as boilers. If the heating source is a heat pump, the system flow temperature will be reduced, leading to a decrease in the heat output achieved by the UFH system. If the mean water temperature is 40ºC, the heating output will decrease by an estimated 20%, and if the mean water temperature is 35ºC, the heating output will decrease by an estimated 40%.
*Check the maximum floor surface temperature is suitable in accordance with the floor finish manufacturer guidelines.
Cli-Mate Single Room Kit includes the following:
- Manifold includes bracket; automatic air vent; drain fill valves and pressure gauge
- Euroconus fittings to connect pipe to manifold
- Clips for fixing pipe to floor insulation
- Underfloor Heating pipe PE-RT UFH Barrier Pipe
- Pump set
- Set of Ball Valves
- Edging insulation – 150mm x 8mm x 50m
- Pipe Bends
Please see a list of materials provided with each pack. (Actuators and Controls are sold separately).
Pack Size |
Manifold Port Size |
Total Amount of Pipe (metres) |
Total No. Pipe Connectors |
Total No. Of Clips | Total No. Pipe Bends | Total No. Of Pump Sets |
Edging Insulation (metres) |
30m² – 2 Zone Pack | 2 | 240 | 4 | 200 | 4 | 1 | 50 |
40m² – 2 Zone Pack | 2 | 240 | 4 | 400 | 4 | 1 | 50 |
60m² – 3 Zone Pack | 3 | 360 | 6 | 500 | 6 | 1 | 50 |
80m² – 4 Zone Pack | 4 | 480 | 8 | 500 | 8 | 1 | 50 |
100m² – 5 Zone Pack | 5 | 500 | 10 | 1000 | 10 | 1 | 50 |
120m² – 6 Zone Pack | 6 | 620 | 12 | 1000 | 12 | 1 | 100 |
140m² – 7 Zone Pack | 7 | 740 | 14 | 1000 | 14 | 1 | 100 |
160m² – 8 Zone Pack | 8 | 860 | 16 | 1000 | 16 | 1 | 100 |
180m² – 9 Zone Pack | 9 | 980 | 18 | 1000 | 18 | 1 | 100 |
200m² – 10 Zone Pack | 10 | 1000 | 20 | 1200 | 20 | 1 | 100 |
Controls can be purchased separately click here.