Cli-Mate Wet Underfloor Heating Standard Output Kit – 30m² to 200m²
The Cli-Mate Wet Underfloor Heating Standard Output systems are perfect for homeowners and tradespeople. These kits are designed for single-room temperature control on the ground floor. They are ideal for both new builds and renovation projects with solid floor constructions. You can fit the pipes onto floor insulation using clips. Then, cover them with screed before you lay the floor covering. Each kit covers a specific area in square meters. We base this on a 200mm pipe spacing. The kit provides a certain heating output based on this spacing.
| Standard Output Pack: Estimated heating output | ||||
| Proposed Floor Finish | Thermal Resistance (Estimate) | Pipe Spacing (mm) | Maximum UFH Output W/m² | *Floor Surface Temperature (ºC) |
| Tile / Stone | 0.02 W/m²K | 200 | 115 | 30 |
| Vinyl | 0.05 W/m²K | 200 | 90 | 28 |
| Timber | 0.10 W/m²K | 200 | 75 | 27 |
| Carpet | 0.15 W/m²K | 200 | 65 | 26 |
*Check the maximum floor surface temperature with the floor finish manufacturer’s guidelines.
The estimated heating outputs are based on achieving a 20ºC internal room temperature. This assumes a mean water temperature of 45ºC (50ºC Flow, 40ºC Return). These figures are suitable for systems that use conventional heat sources, such as boilers.
However, if a heat pump is the heating source, the system flow temperature will decrease. Consequently, the UFH system’s heat output will also decrease. For example, if the mean water temperature is 40ºC, the heating output will decrease by an estimated 20%. Furthermore, if the mean water temperature is 35ºC, the heating output will decrease by an estimated 40%.
What’s Included in the Kit?
The Cli-Mate Single Room Kit includes:
- Manifold: A manifold with a bracket, automatic air vent, drain fill valves, and a pressure gauge.
- Fittings: Euroconus fittings to connect the pipe to the manifold.
- Clips: Clips for fixing the pipe to the floor insulation.
- Pipe: Underfloor heating pipe PE-RT UFH Barrier Pipe.
- Pump Set: A pump set.
- Ball Valves: A set of ball valves.
- Edging Insulation: 150mm x 8mm x 50m edging insulation.
- Pipe Bends: Pipe bends.
(Actuators and Controls are sold separately.)
Please see the table below for a list of materials provided with each pack.
| Pack Size | Manifold Port Size | Total Amount of Pipe (metres) | Total No. Pipe Connectors | Total No. Of Clips | Total No. Pipe Bends | Total No. Of Pump Sets | Edging Insulation (metres) |
| 30m² – 2 Zone Pack | 2 | 240 | 4 | 200 | 4 | 1 | 50 |
| 40m² – 2 Zone Pack | 2 | 240 | 4 | 400 | 4 | 1 | 50 |
| 60m² – 3 Zone Pack | 3 | 360 | 6 | 500 | 6 | 1 | 50 |
| 80m² – 4 Zone Pack | 4 | 480 | 8 | 500 | 8 | 1 | 50 |
| 100m² – 5 Zone Pack | 5 | 500 | 10 | 1000 | 10 | 1 | 50 |
| 120m² – 6 Zone Pack | 6 | 620 | 12 | 1000 | 12 | 1 | 100 |
| 140m² – 7 Zone Pack | 7 | 740 | 14 | 1000 | 14 | 1 | 100 |
| 160m² – 8 Zone Pack | 8 | 860 | 16 | 1000 | 16 | 1 | 100 |
| 180m² – 9 Zone Pack | 9 | 980 | 18 | 1000 | 18 | 1 | 100 |
| 200m² – 10 Zone Pack | 10 | 1000 | 20 | 1200 | 20 | 1 | 100 |
Controls can be purchased separately click here.